For the Valet Manager POS to communicate with the PAX terminals, the following settings must be configured as follows:
- TAB - Communication
- SECTION - General
- Primary Comm Type -LAN
- SECTION - LAN
- LAN Update -ON
- DHCP -Disabled
- Local IP - 192.168.009.049 [If there is more than 1 terminal at a location, please contact your valet manager representative to confirm the correct IP addresses.]
- Netmask - 255.255.255.000
- Gateway IP - 192.168.009.001
- DNS IP - 008.008.008.008
- Ping URL -www.google.com
- Ping Timeout (ms)- 500
- SECTION - Communication between ECR/POS and PAX terminal
- Limit Length -512
- Port -10009
- Communication Type -Ethernet
- UART Baudrate -9600 bps
- Protocol Type -TCP/IP
- SECTION - General
- TAB - Industry
- SECTION - Host Features
- Local Duplicate Check -Enabled
- SECTION - Host Features
We do recommend the following settings to reduce confusion between attendants and customers.
- TAB - BroadPOS
- Time and Date Synchronization
- TimeZone -Select terminal's actual timezone
- Daylight Savings Time -Enable
- Sync to Server Time -Enable
- Time and Date Synchronization
- TAB - EMV
- SECTION - EMV Features
- EMV Card Remove Beep -Continuous Beep
- SECTION - EMV Features
- TAB - Industry
- SECTION - Host Features
- Fleet Card Support -Enabled
- Commercial Card Support -Enabled
- FSA Support -Disabled
- Disable Feet Card Prompts -Yes
- Disable Commercial Card Prompts -Yes
- SECTION - Host Features
- TAB - Misc
- SECTION - Peripherals Features
- Contactless Module -Internal
- SECTION - Peripherals Features
** For PAX Android terminals please ensure that the BroadPOS application is either pinned or set to auto-launch in AirLauncher.